Model NO.: OX2/231
Power Source: AC220V
Certifications: ISO Ce
Warranty: 12 Months
After-Service: Online, in Field
Trademark: Labthink
Transport Package: Veneer Case
Origin: Shandong
Model NO.: OX2/231
Power Source: AC220V
Certifications: ISO Ce
Warranty: 12 Months
After-Service: Online, in Field
Trademark: Labthink
Transport Package: Veneer Case
Origin: Shandong
Paper Plastic Composite Film Oxygen Transmission Rate Test SystemOX2/231 is based on the equal pressure method, and is professional applicable to the determination of oxygen transmission rate of film and package products, including plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.

Features
- Tests 3 equivalent specimens at one operation and exports test results in average value
- 2 test modes for both films and packages, and accessories for package test are available for customization
- Equipped with constant temperature and humidity control devices (optional parts) to meet different test requirements
- Reference film for fast calibration to ensure accurate and universal test data
- The instrument is controlled by micro-computer with LCD, menu interface and PVC operating panel, which could conveniently export test data, test results and test curves
Â
|
|
|
Specifications
Â
Specifications | Film Test |
Package Test
(customization available)
|
---|---|---|
Test Range | 0.01 ~ 1000 cm3/m2·d (standard) 0.1 ~ 10,000 cm3/m2·d (optional) |
0.0001 ~ 10 cm3/pkg·d (standard) |
Number of Specimens | 1 ~ 3 | |
Resolution | 0.01 cm3/m2·d | 0.0001 cm3/pkg·d |
Temperature Range | 15°C ~ 55°C (optional) | / |
Temperature Accuracy | ±0.1°C | / |
Humidity Range | 0%RH, 15%RH ~ 90%RH, 100%RHÂ (optional) |
|
Humidity Accuracy | ±1%RH | |
Test Gas | O2Â and air (outside of supply scope) | |
Test Area | 50 cm2 | / |
Thickness | ≤3 mm (customization is available for other thickness) | / |
Specimen Size | 108 mm x 108 mm | Test in 100% O2: Specimen should be smaller than Ф120 mm and lower than 360 mm |
Test in the Air: No size limitation | ||
Bottles: the inner diameter should be bigger than Ф8 mm, outer diameter should be smaller than Ф42 mm (Standard) | ||
Bags or Boxes: Supported by accessories | ||
Carrier Gas | High purity nitrogen with more than 99.999% concentration (outside of supply scope) |
Standards
ISO 15105-2, GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, JIS K7126-2, YBB00082003
Paper Plastic Composite Film Oxygen Transmission Rate Test SystemOX2/231 is based on the equal pressure method, and is professional applicable to the determination of oxygen transmission rate of film and package products, including plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.

Features
- Tests 3 equivalent specimens at one operation and exports test results in average value
- 2 test modes for both films and packages, and accessories for package test are available for customization
- Equipped with constant temperature and humidity control devices (optional parts) to meet different test requirements
- Reference film for fast calibration to ensure accurate and universal test data
- The instrument is controlled by micro-computer with LCD, menu interface and PVC operating panel, which could conveniently export test data, test results and test curves
Â
|
|
|
Specifications
Â
Specifications | Film Test |
Package Test
(customization available)
|
---|---|---|
Test Range | 0.01 ~ 1000 cm3/m2·d (standard) 0.1 ~ 10,000 cm3/m2·d (optional) |
0.0001 ~ 10 cm3/pkg·d (standard) |
Number of Specimens | 1 ~ 3 | |
Resolution | 0.01 cm3/m2·d | 0.0001 cm3/pkg·d |
Temperature Range | 15°C ~ 55°C (optional) | / |
Temperature Accuracy | ±0.1°C | / |
Humidity Range | 0%RH, 15%RH ~ 90%RH, 100%RHÂ (optional) |
|
Humidity Accuracy | ±1%RH | |
Test Gas | O2Â and air (outside of supply scope) | |
Test Area | 50 cm2 | / |
Thickness | ≤3 mm (customization is available for other thickness) | / |
Specimen Size | 108 mm x 108 mm | Test in 100% O2: Specimen should be smaller than Ф120 mm and lower than 360 mm |
Test in the Air: No size limitation | ||
Bottles: the inner diameter should be bigger than Ф8 mm, outer diameter should be smaller than Ф42 mm (Standard) | ||
Bags or Boxes: Supported by accessories | ||
Carrier Gas | High purity nitrogen with more than 99.999% concentration (outside of supply scope) |
Standards
ISO 15105-2, GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, JIS K7126-2, YBB00082003