Analytical pump and conveyor type: Tandem double-piston reciprocating pump, microprocessor controlled stroke, variable speed construction: chemically inert, non-metallic PEEK pump head and flow path PH: 0-14 aqueous solution and reversed solvent compatible control mode : Through the front panel or through chameleon software full control; TTL or relay switch selectable maximum operating pressure: 35Mpa (5000psi)
Pressure fluctuation: <1.0%
Flow rate range: 0.05-5.0 mL/min in increments of 0.01;
Flow accuracy: <0.1%
Flow accuracy: ±0.1%,
Piston seal cleaning: Double pump head, continuous cleaning pressure alarm limit when connecting washing liquid: upper limit 0-35Mpa or 0-5000psi in one unit increment (MPa or psi); lower limit can be set one unit lower than the upper limit.
Vacuum Degassing (Optional): Automatic Column Heating Operating Temperature Range: Environment +5°C to 60°C
Temperature stability: ±1°C
Temperature accuracy: ±2°C (at 40°C)
Eluent automatic generator concentration range: 0.1-100 mM
Flow rate range: 0.1-3.0mL/min
Maximum operating pressure: 21Mpa (3000psi)
Maximum solvent concentration: Anion: 25%Mathanol; Cation: Solvent-free conductivity detection circuit and flow cell type: Microprocessor - Digital signal processor Linearity: 1% at 1mS Resolution: 0.00238nS
Detection range: digital mode 0-15000μS;
Filter: start time from 0 to 10 seconds, user selectable temperature compensation: fixed at 1.7% for 1°C
Conductivity cell temperature control temperature range: environment +7°C to 55°C
Temperature stability: ≤0.01°C
Conductivity Cell Electrode: Passivated 316 Stainless Steel Conductive Cell Body Material: Chemically Inert Polymeric Material Conductance Cell Volume: <1 μL
Chi-plus heat exchanger: low differential maximum pool operating pressure: 10MPa
Suppressor control power supply:
AESR, 0-150mA, 1mA increments;
SRS, 0-500mA, 1mA Incremental Physical Specifications Power Supply: 100-240V AC, 50/60Hz (Automatic sensing and regulation)
Voltage range: 90-265V AC, 47-63Hz
Instrument operating temperature: 4-40°C (40-104°F)
Operating Humidity Range: 5-95% Relative Humidity, Non-condensing Control Mode: Controlled by chameleon software, TTL or delay switch can be selected. Two delayed outputs, two TTL outputs, four programmable input USB communication ports: One input, two fixed USB input ports Leak detection: built-in, optical sensor size (h × w × d) 22.1in × 8.8in × 21in; 56.1cm x 22.4cm x 53.3cm
Weight: 54 lbs, 24.5 kg AS40 Autosampler Specifications Vial Size and Texture: 0.5mL or 5mL Vial, Polyvial
Sample capacity: 11 trays 6x5mL or 8x0.5mL
Minimum liquid supply: 0.5mL bottle: 0.17mL/time 5mL bottle: 1.7mL/time per bottle Injection time: 1, 2 or 3
Injection method: Loop: Rapid injection (about 4 mL/min)
Concentration: 0.4mL/min (0.5mL bottle) under 690kPa (100psi) back pressure
Or 0.1mL/min (5mL bottle)
Voltage: 90-165Vac, 47-63Hz
Volume: 28.7X36.3X44.5cm (11.3X14.3X17.5in.)
Weight: <8.9kg (<195 lb)
CNC machining/lathe machining turning is the workpiece is fixed on the lathe, using high speed rotating machine drives the workpiece, the turning. tool on the workpiece so the product shape is round. The maximum of our machines can clip the weight of 200Kg, maximum diameter of 450mm, length of 750mm. high speed 3000RPM. processing materials are commonly used in steel, copper, aluminum, stainless steel POM, PS, PMMA, and other metal and plastic. The CNC machining turning precision of 0.01mm. concentric 0.01. we have specialized equipment to test products, these instruments include: TESA Grohe, micrometer, projector, calipers. Product surface treatment has anode, electroplating, sand blasting, passivation, surface drawing, spraying, laser carving, such as LOGO, etc..CNC machining Turning application in a variety of industries, including: cars, ships, communications, medical equipment, industrial automation equipment.