First, sewage electromagnetic flowmeter communication method 1, after the connection line to the electromagnetic flowmeter power, enter the parameter setting screen, set the flowmeter communication address and communication speed.
2. On the CD, you can see two folders named "WIN98" and "WINXP". Select one of them according to your computer's system (WIN2000 also uses WinXP). There is a name in the folder. For the "SETUP" file, double-click to enter the installation state, and then follow the prompts.
3. After the installation is complete, you can see a new program named L-mag(51) is added in the start menu program. Click to open the communication test program.
4. Set the communication port on the software (some computers have two serial ports, only one serial port is set to com1), communication address and communication speed make him the same as you set in the electromagnetic flowmeter, click Start.
5. In this way, the corresponding data such as instantaneous flow rate and flow rate will be displayed on your PC. Click the multi-machine communication in the above communication menu to enter the multi-machine display.
6. The software automatically searches for the communication address. Click the menu above to display the data of multiple electromagnetic flowmeters. The data on the comparison computer should be the same as the data displayed by the electromagnetic flowmeter.
Second, sewage electromagnetic flowmeter communication protocol MAG5_MDBRTUV1.3 communication protocol uses the standard MODBUSRTU communication protocol. The MAG511 meter is a slave.
1. RTU message frame definition The data communication is initiated by the host. The host first sends the RTU message frame. The message frame transmission starts with a pause interval of at least 3.5 characters. The first byte of the transfer is the device address. The transfer characters that can be used are hexadecimal 0...9, A...F. All slave devices constantly detect the network bus, including pauses. When the first address byte is received, each device decodes it to determine if it is destined for itself. A pause of at least 3.5 characters marks the end of the message after the last transmitted character. A new message can start after this pause.
The entire message frame must be transmitted as a continuous stream. If there is a pause of more than 1.5 characters before the frame is completed, the receiving device will flush the incomplete message and assume that the next byte is the address field of a new message. Similarly, if a new message starts with the previous message in less than 3.5 character time, the receiving device will consider it to be a continuation of the previous message. This will cause an error because the value in the last CRC field cannot be correct. The message frame definition is as follows:
RTU message frame basic definition 01234567
Device Address Function Code Address 1 Address 0 Data 1 Data 0 CRC CRC
8-bit byte 8-bit byte 8-bit byte 8-bit byte 8-bit byte 8-bit byte 8-bit byte 8-bit byte 2 Parameter readout command Function code 3: Read holding register (Details see Appendix A modbus protocol description Table 1 page 42)
Host command slave address + function code + desired prefix address + number of desired characters + check digit (CRC)
1byte+1byte+2bytes+2bytes+2bytes
1) Host command format 01234567
Device Address Function Code Address 1 Address 0 Data 1 Data 0 CRC CRC
1~9903000--3501XXXX
Address 1 and address 0 are the upper and lower bits of the word-to-be-read address, and data 1 and data 0 are the upper and lower bits of the number of words to be read.
Slave sendback slave address + function code + number of read words + byte content + check digit (CRC)
1byte+1byte+1byte+nbytes+2bytes
2). Slave response format 0123456
Device Address Function Code Number of bytes Data 1 Data 0 CRC CRC
1~99032 high byte low byte XXXX
Data = 256 * data 1 + data 0;
Note: When reading out, the parameter number is incremented by 1 (defined by the MODBUS protocol). If the parameter number of the host command is 08, the parameter number read out is 09.
Sewage electromagnetic flowmeter
Nickel-based alloy powders are commonly used in plasma transfer arc welding (PTAW) due to their excellent corrosion resistance, high temperature strength, and good weldability. These alloys are typically composed of nickel as the base metal, with various alloying elements added to enhance specific properties.
Some commonly used nickel-based alloy powders for PTAW include:
1. Inconel 625: This alloy powder is widely used for PTAW due to its high strength, excellent resistance to corrosion, and oxidation at elevated temperatures. It is commonly used in applications involving seawater, chemical processing, and aerospace industries.
2. Hastelloy X: This alloy powder is known for its high-temperature strength and oxidation resistance. It is commonly used in applications involving gas turbine engines, industrial furnace components, and chemical processing.
3. Monel 400: This alloy powder is known for its excellent resistance to corrosion, particularly in marine environments. It is commonly used in applications involving seawater, chemical processing, and oil refining.
4. Inconel 718: This alloy powder is known for its high strength, excellent resistance to corrosion, and good weldability. It is commonly used in applications involving aerospace, oil and gas, and nuclear industries.
5. Inconel 601: This alloy powder is known for its excellent resistance to high-temperature oxidation and corrosion. It is commonly used in applications involving heat treatment equipment, chemical processing, and power generation.
These nickel-based alloy powders can be used in PTAW processes to create high-quality welds with excellent mechanical properties and resistance to corrosion and high temperatures.
Inconel Powder,Nickel Powder,Pta Welding Ni Alloy Powder,Laser Cladding Ni Base Powder
Luoyang Golden Egret Geotools Co., Ltd , https://www.xtclasercladding.com